Back

zws-15/CI/QS

  • 1 x analogue 4-20 mA
  • 250 mm
20 - 250 mm
cuboidal
analogue distance measurements
small cuboidal design
narrow sound field
echo propagation time measurement
380 kHz
20 mm
150 mm
250 mm
0.20 mm
± 0.15 %
± 1 % (temperature drift internally compensated)
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 25 mA
4-pin M8 initiator plug
analogue output
current: 4-20 mA
switchable rising/falling
50 ms
< 300 ms
external synchronisation from rectangular signal with a defined pulse width
synchronisation input
ABS
polyurethane foam, epoxy resin with glass contents
IP 67
-25°C to +70°C
-40°C to +85°C
10 g
zws-15/SI/CI/QS
yes
1 push-button
Teach-in via push-button
yes
no
1 x LED green: working, 1 x LED yellow: object in the window
small cuboidal design
narrow sound field
zws-15/CI/QS