Back

mic-600/IU/M

  • 1 x analogue 4-20 mA + 0-10 V
  • 8,000 mm
600 - 8.000 mm
cylindrical M30
analogue distance measurements
metal plug for harsh operational conditions
echo propagation time measurement
80 kHz
600 mm
6,000 mm
8,000 mm
0.18 mm to 2.4 mm, depending on the analogue window
± 0.15 %
± 1 % (temperature drift internally compensated)
9 - 30 V d.c., reverse polarity protection
± 10 %
≤ 55 mA
5-pin M12 initiator plug
analogue output
current: 4-20 mA / voltage: 0-10 V (at UB ≥ 15 V), short-circuit-proof
switchable rising/falling
240 ms
< 600 ms
com input
teach-in input
brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
IP 67
-25°C to +70°C
-40°C to +85°C
320 g
cable connection (on request)
yes
com input
control input
Teach-in via com input on pin 5
LCA-2 with LinkControl
yes
no
no
metal plug for harsh operational conditions
mic-600/IU/M