- 1 x analogue 0-10 V
- 350 mm
30 - 350 mm
cylindrical M18 with radially-arranged ultrasonic transducer (90° angular head)
analogue distance measurements
90° angular head
UL Listed
UL Listed
echo propagation time measurement
320 kHz
30 mm
250 mm
350 mm
0.069 mm to 0.10 mm, depending on the analogue window
± 0.15 %
± 1 % (temperature drift internally compensated)
15 V bis 30 V DC, verpolfest
± 10 %
≤ 40 mA
5-pin M12 initiator plug
analogue output
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
voltage: 0-10 V, short-circuit-proof
switchable rising/falling
32 ms
< 300 ms
com input
synchronisation input
teach-in input
synchronisation input
teach-in input
brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
15 Nm
IP 67
-25°C to +70°C
-40°C to +85°C
35 g
yes
com input
Teach-in via com input on pin 5
LCA-2 with LinkControl
LCA-2 with LinkControl
yes
yes
1 x LED green: working, 1 x LED yellow: object in the window
90° angular head
UL Listed
UL Listed
pico+25/WK/U