Back

dbk+4/M12/3CDD/M18 E+S

  • 2 x pnp
papers with weights of 20 - 600 g/m2, Washi, metal-laminated sheets and films up to 0.2 mm thick, self-adhesive films
cylindrical M12 with a swapped-out ultrasonic transducer
double sheet control
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection
pulse operation with amplitude evaluation
500 kHz
5 mm in front of transmitter and receiver
20 - 30 V d.c., reverse polarity protection
± 10 %
≤ 50 mA
2 m PUR cable, 7 x 0.14 mm2
am Empfänger: 1,2 m PUR-Kabel, am Sender: 1 m PUR-Kabel, mit M8 Rundsteckverbinder; zum ausgelagerten Empfangswandler: 1,2 m PVC-Kabel
double sheet output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
missing sheet output
pnp: Imax = 200 mA (UB-2V)
NOC/NCC adjustable, short-circuit-proof
< 500 µs in trigger mode, 2.5 ms in free-run mode
< 300 ms
< -UB+18 V: logic 1; > -UB+13 V or control input open: logic 0
control input
control input
control input
20 - 40 mm; optimal: 20 mm ± 2 mm
± 45° from the perpendicular to the sheet
brass sleeve, nickel-plated, plastic parts, PBT, PA
polyurethane foam, epoxy resin with glass contents
M18: 15 Nm, M12: 3 Nm
IP 65
+5°C to +60°C
-40°C to +85°C
160 g
single transmitter/receiver
control input
working range selection via control inputs
Teach-in via control inputs
LCA-2 with LinkControl
1 x Duo-LED; green: working / red: double sheet / flashing red: missing sheet
distance between transmitter and receiver can be selected
swapped-out ultrasonic transducer
M12
cable connection
dbk+4/M12/3CDD/M18 E+S