• archivsensoren_1046x850.jpg

Back

archiv sensor  lcs-30/IU/HV/QP/K10

  • lcs-30/IU/HV/QP/K10

Page content as online catalogue (download)

download sensor line as pdf

Download complete sensor range as PDF

please ask about
  • 1 x analogue 4-20 mA + 0-10 V
  • 600 mm
65 - 350 mm
cuboidal
analogue distance measurements
archive sensor
flat housing
lateral sound exit
cable connection
echo propagation time measurement
400 kHz
60 mm
350 mm
600 mm
0.36 mm
± 0.15 %
± 1 % (temperature drift internally compensated)
12 - 30 V d.c., reverse polarity protection
± 10 %
≤ 70 mA
10 m PUR cable, 5 x 0.25 mm2
analogue output
current: 4-20 mA / voltage: 0-10 V (at UB ≥ 15 V), short-circuit-proof
switchable rising/falling
70 ms
< 300 ms
com input
PBT
polyurethane foam, epoxy resin with glass contents
IP 65
-20°C to +70°C
-40°C to +85°C
yes
no
LCA-2 with LinkControl
no
no
2 x three-colour LED
archive sensor
flat housing
lateral sound exit
cable connection
LCA-2
LCA-2 Koffer
lcs-30/IU/HV/QP/K10