wms-600/RT
  • echo output
  • 8,000 mm
800 - 8.000 mm
cylindrical M30
sensor for evaluators
archive sensor
echo propagation time measurement
80 kHz
800 mm
6,000 mm
8,000 mm
± 0.15 %
temperature drift 0.17 %/K
10 - 30 V d.c., reverse polarity protection
± 10 %
≤ 30 mA
4-pin M12 initiator plug
signal output echo
pnp: Imax = 10 mA (signal output echo)
350 µs
65 ms
controlled by open collector (npn), IC ≥ 3 mA, UCE ≥ 30 V
signal input - transmitter
brass sleeve, nickel-plated, plastic parts, PBT
polyurethane foam, epoxy resin with glass contents
IP 65
-20°C to +70°C
-40°C to +85°C
340 g
stainless steel
cable connection (on request)
durch Ulraschall-Referenzmessung
no
no
yes
yes
no
archive sensor
wms-601/RT/HV/M30